NORMOPERF | Normothermic perfusion devices for renal and hepatic preservation and viability assessment

Summary
Organ transplantation is the best available technique for the treatment of end-stage failure of most essential organs. However, the further development of transplantation is being hampered by the scarcity of available organs and the limitations of static cold preservation: lack of information about the organ function and viability, ischemia-reperfusion injury, short preservation times and poor compatibility with suboptimal organs.

Our solution to overcome these limitations consists in a portable medical device that is capable of maintaining the human kidney or liver in a viable state for sustained periods under physiological conditions ex vivo by means of a normothermic perfusion of the organ with a preservation solution that delivers oxygen, nutrients and chemical signals. Through maintaining the physiological cellular metabolism, it is possible to prolong the preservation times, reduce to a minimum ischemia-reperfusion injury, assess the organ viability and function by means of monitoring key parameters and increase the number of available organs.

Our envisaged final solution consists in a product with three elements: the perfusion machine and two single-use consumables: the perfusion circuit and the preservation solution. Specific versions of the consumables will be available for each organ type (liver or kidney), but all of them will be compatible with the same perfusion machine. The product will address a global market, focusing initially on the EU and in a second phase on the USA.

EBERS has a fully functional prototype of the device, validated and demonstrated using a porcine transplant model. In Phase 1 of the project, IP and regulatory strategies will be refined, the product concept will be validated, further market knowledge will be gained and the commercialisation plan will be detailed. In Phase 2, the prototype will be industrialised, a clinical assay will be performed and the device will receive CE-mark approval, becoming a market ready product.
Unfold all
/
Fold all
More information & hyperlinks
Web resources: https://cordis.europa.eu/project/id/729703
Start date: 01-05-2016
End date: 31-10-2016
Total budget - Public funding: 71 429,00 Euro - 50 000,00 Euro
Cordis data

Original description

Organ transplantation is the best available technique for the treatment of end-stage failure of most essential organs. However, the further development of transplantation is being hampered by the scarcity of available organs and the limitations of static cold preservation: lack of information about the organ function and viability, ischemia-reperfusion injury, short preservation times and poor compatibility with suboptimal organs.

Our solution to overcome these limitations consists in a portable medical device that is capable of maintaining the human kidney or liver in a viable state for sustained periods under physiological conditions ex vivo by means of a normothermic perfusion of the organ with a preservation solution that delivers oxygen, nutrients and chemical signals. Through maintaining the physiological cellular metabolism, it is possible to prolong the preservation times, reduce to a minimum ischemia-reperfusion injury, assess the organ viability and function by means of monitoring key parameters and increase the number of available organs.

Our envisaged final solution consists in a product with three elements: the perfusion machine and two single-use consumables: the perfusion circuit and the preservation solution. Specific versions of the consumables will be available for each organ type (liver or kidney), but all of them will be compatible with the same perfusion machine. The product will address a global market, focusing initially on the EU and in a second phase on the USA.

EBERS has a fully functional prototype of the device, validated and demonstrated using a porcine transplant model. In Phase 1 of the project, IP and regulatory strategies will be refined, the product concept will be validated, further market knowledge will be gained and the commercialisation plan will be detailed. In Phase 2, the prototype will be industrialised, a clinical assay will be performed and the device will receive CE-mark approval, becoming a market ready product.

Status

CLOSED

Call topic

SMEInst-05-2016-2017

Update Date

26-10-2022
Images
No images available.
Geographical location(s)
Structured mapping
Unfold all
/
Fold all
Horizon 2020
H2020-EU.2. INDUSTRIAL LEADERSHIP
H2020-EU.2.3. INDUSTRIAL LEADERSHIP - Innovation In SMEs
H2020-EU.2.3.1. Mainstreaming SME support, especially through a dedicated instrument
H2020-SMEINST-2-2016-2017
SMEInst-05-2016-2017 Supporting innovative SMEs in the healthcare biotechnology sector
H2020-EU.3. SOCIETAL CHALLENGES
H2020-EU.3.1. SOCIETAL CHALLENGES - Health, demographic change and well-being
H2020-EU.3.1.0. Cross-cutting call topics
H2020-SMEINST-2-2016-2017
SMEInst-05-2016-2017 Supporting innovative SMEs in the healthcare biotechnology sector
H2020-EU.3.1.3. Treating and managing disease
H2020-EU.3.1.3.0. Cross-cutting call topics
H2020-SMEINST-1-2016-2017
SMEInst-05-2016-2017 Supporting innovative SMEs in the healthcare biotechnology sector
H2020-SMEINST-2-2016-2017
SMEInst-05-2016-2017 Supporting innovative SMEs in the healthcare biotechnology sector