Nuventura | Novel dry air switchgear technology to reduce industry’s dependence on SF6

Summary
Nuventura develops medium voltage (MV) gas insulated switchgear (GIS) which replaces SF6 - the world's strongest greenhouse gas - with dry air. Annual SF6 emissions are 8,100 t, equal to the CO2 emissions by 100m cars. 85% of SF6 gas is used as a GIS insulating medium. Though recycling of SF6 is possible, it is usually not done due to difficulty & cost. It can be expected that SF6 that exists now & that is produced in the future will persist for thousands of years, whether in GIS equipment or, ultimately, in the atmosphere. SF6' atmospheric lifetime is 3,200 years. MV power grids (12-40.5 kV) use 3 types of switchgear: air insulated switchgear (AIS), solid insulated switchgear (SIS) & gas insulated switchgear (GIS). AIS have a large physical footprint, costly maintenance, & inability to meet the demands of urban grids. SIS works only in rare & highly specialized use cases. Nuventura combines the advantages of GIS & AIS in a new dry air switchgear that is sustainable, safe & reliable.
Unfold all
/
Fold all
More information & hyperlinks
Web resources: https://cordis.europa.eu/project/id/190181312
Start date: 01-11-2022
End date: 30-04-2025
Total budget - Public funding: 3 543 125,00 Euro - 2 480 187,00 Euro
Cordis data

Original description

Nuventura develops medium voltage (MV) gas insulated switchgear (GIS) which replaces SF6 - the world's strongest greenhouse gas - with dry air. Annual SF6 emissions are 8,100 t, equal to the CO2 emissions by 100m cars. 85% of SF6 gas is used as a GIS insulating medium. Though recycling of SF6 is possible, it is usually not done due to difficulty & cost. It can be expected that SF6 that exists now & that is produced in the future will persist for thousands of years, whether in GIS equipment or, ultimately, in the atmosphere. SF6' atmospheric lifetime is 3,200 years. MV power grids (12-40.5 kV) use 3 types of switchgear: air insulated switchgear (AIS), solid insulated switchgear (SIS) & gas insulated switchgear (GIS). AIS have a large physical footprint, costly maintenance, & inability to meet the demands of urban grids. SIS works only in rare & highly specialized use cases. Nuventura combines the advantages of GIS & AIS in a new dry air switchgear that is sustainable, safe & reliable.

Status

SIGNED

Call topic

HORIZON-EIC-2022-ACCELERATORCHALLENGES-02

Update Date

09-02-2023
Images
No images available.
Geographical location(s)
Structured mapping
Unfold all
/
Fold all
Horizon Europe
HORIZON.3 Innovative Europe
HORIZON.3.1 The European Innovation Council (EIC)
HORIZON.3.1.0 Cross-cutting call topics
HORIZON-EIC-2022-ACCELERATOR-01
HORIZON-EIC-2022-ACCELERATORCHALLENGES-02 EIC Accelerator Challenge: Technologies for ‘Fit for 55’