MAGRITTE | Recovering plasma-facing components temperatures in fusion devices from IR camera measurements

Summary
Infrared (IR) cameras are key diagnostics to monitor and control plasma-facing components (PFCs) in fusion devices. Nevertheless, the use of all-metallic PFCs with low and variable emissivity (ε ~ 0.1-0.5) makes it difficult to obtain a correct surface temperature measurement. The radiance collected by the IR camera includes both the thermal radiation emitted by the target and parasitic radiation coming from the target's surroundings. Furthermore, target emissivity changes with the surface temperature and roughness. This causes significant errors in the surface temperature measurement that we need to address for achieving high power and safe plasma operation. Inaccurate interpretation of IR temperature measurement could endanger machine safety (temperature underestimation) or on the contrary, lead to unnecessary pulse interruptions that reduce the overall performance of the machine (temperature overestimation). The current approach is to convert the radiance collected by each pixel in an apparent using a physical relationship between emitted radiance and temperature (Planck’s law). Because a portion of the collected radiance is due to reflection on the target, a systematic error is made. This method is unable to recover the portion of reflected radiance and to deduce the correct temperature of the target using only the emitted radiance. The proposed technique in this project is to use a digital twin of the machine and to make in it assumptions on the temperatures of the different elements of the machine in order to simulate the images that would be measured under these supposed conditions. By comparing to the real image measured by the camera and using optimization techniques, the assumptions on the parameters can be updated until the simulated and measured images are close enough. It is then deduced that the assumptions made on the parameters of the digital twin are correct and that they correspond to the real temperatures in the machine.
Unfold all
/
Fold all
More information & hyperlinks
Web resources: https://cordis.europa.eu/project/id/101130874
Start date: 01-09-2024
End date: 31-08-2026
Total budget - Public funding: - 171 399,00 Euro
Cordis data

Original description

Infrared (IR) cameras are key diagnostics to monitor and control plasma-facing components (PFCs) in fusion devices. Nevertheless, the use of all-metallic PFCs with low and variable emissivity (ε ~ 0.1-0.5) makes it difficult to obtain a correct surface temperature measurement. The radiance collected by the IR camera includes both the thermal radiation emitted by the target and parasitic radiation coming from the target's surroundings. Furthermore, target emissivity changes with the surface temperature and roughness. This causes significant errors in the surface temperature measurement that we need to address for achieving high power and safe plasma operation. Inaccurate interpretation of IR temperature measurement could endanger machine safety (temperature underestimation) or on the contrary, lead to unnecessary pulse interruptions that reduce the overall performance of the machine (temperature overestimation). The current approach is to convert the radiance collected by each pixel in an apparent using a physical relationship between emitted radiance and temperature (Planck’s law). Because a portion of the collected radiance is due to reflection on the target, a systematic error is made. This method is unable to recover the portion of reflected radiance and to deduce the correct temperature of the target using only the emitted radiance. The proposed technique in this project is to use a digital twin of the machine and to make in it assumptions on the temperatures of the different elements of the machine in order to simulate the images that would be measured under these supposed conditions. By comparing to the real image measured by the camera and using optimization techniques, the assumptions on the parameters can be updated until the simulated and measured images are close enough. It is then deduced that the assumptions made on the parameters of the digital twin are correct and that they correspond to the real temperatures in the machine.

Status

SIGNED

Call topic

HORIZON-WIDERA-2022-TALENTS-04-01

Update Date

31-07-2023
Images
No images available.
Geographical location(s)
Structured mapping
Unfold all
/
Fold all
Horizon Europe
HORIZON.4 Widening Participation and Strengthening the European Research Area
HORIZON.4.1 Widening participation and spreading excellence
HORIZON.4.1.5 Fostering brain circulation of researchers and excellence initiatives
HORIZON-WIDERA-2022-TALENTS-04
HORIZON-WIDERA-2022-TALENTS-04-01 Fostering balanced brain circulation – ERA Fellowships