Summary
The detection of dilute populations of nanoparticles in microfluidics is difficult due to diffusion as the time limiting step to reach the sensor. Using active transport, we propose to build a proof of concept microfluidic device that reaches sub-attomolar detection sensitivity within an hour and at a device footprint of 1 cm. The active transport enables size separation of the particles into multiple channels and up-concentration in detection reservoirs for label free detection. At the end of the process the size-separated particles can be easily extracted for further downstream processing.
The applied use case is the detection and quantification of virus in drinking water, a global health-critical challenge. A viral concentration of 10-100 particles is infectious in 2l of water consumed by a person, corresponding to a concentration of 10^(-22) molar. Traditional methods rely on multiple concentration steps followed by detection using molecular and/or culture based methods. Most common are adsorption/elution assays which co-concentrate and add contaminations that interfere with the downstream detection analysis. The detection methods are also often specific for the viral type and require a priori identification of the target virus. Metagenomic sequencing allows for general identification but lacks sensitivity.
The proposed method will simplify and improve the process significantly. The viruses will be concentrated without damage of the virus shell and with a high rejection of the contamination present in the sample. All virus particles will be separated and sorted according to predefined size ranges into detection compartments on the chip, allowing for a parallel and quantitative marker-less detection on a single particle level. Specific identification is possible for future devices using (integrated) molecular methods with reduced cross-contamination and without a priori virus identification.
The applied use case is the detection and quantification of virus in drinking water, a global health-critical challenge. A viral concentration of 10-100 particles is infectious in 2l of water consumed by a person, corresponding to a concentration of 10^(-22) molar. Traditional methods rely on multiple concentration steps followed by detection using molecular and/or culture based methods. Most common are adsorption/elution assays which co-concentrate and add contaminations that interfere with the downstream detection analysis. The detection methods are also often specific for the viral type and require a priori identification of the target virus. Metagenomic sequencing allows for general identification but lacks sensitivity.
The proposed method will simplify and improve the process significantly. The viruses will be concentrated without damage of the virus shell and with a high rejection of the contamination present in the sample. All virus particles will be separated and sorted according to predefined size ranges into detection compartments on the chip, allowing for a parallel and quantitative marker-less detection on a single particle level. Specific identification is possible for future devices using (integrated) molecular methods with reduced cross-contamination and without a priori virus identification.
Unfold all
/
Fold all
More information & hyperlinks
Web resources: | https://cordis.europa.eu/project/id/825794 |
Start date: | 01-01-2019 |
End date: | 30-06-2020 |
Total budget - Public funding: | 150 000,00 Euro - 150 000,00 Euro |
Cordis data
Original description
The detection of dilute populations of nanoparticles in microfluidics is difficult due to diffusion as the time limiting step to reach the sensor. Using active transport, we propose to build a proof of concept microfluidic device that reaches sub-attomolar detection sensitivity within an hour and at a device footprint of 1 cm. The active transport enables size separation of the particles into multiple channels and up-concentration in detection reservoirs for label free detection. At the end of the process the size-separated particles can be easily extracted for further downstream processing.The applied use case is the detection and quantification of virus in drinking water, a global health-critical challenge. A viral concentration of 10-100 particles is infectious in 2l of water consumed by a person, corresponding to a concentration of 10^(-22) molar. Traditional methods rely on multiple concentration steps followed by detection using molecular and/or culture based methods. Most common are adsorption/elution assays which co-concentrate and add contaminations that interfere with the downstream detection analysis. The detection methods are also often specific for the viral type and require a priori identification of the target virus. Metagenomic sequencing allows for general identification but lacks sensitivity.
The proposed method will simplify and improve the process significantly. The viruses will be concentrated without damage of the virus shell and with a high rejection of the contamination present in the sample. All virus particles will be separated and sorted according to predefined size ranges into detection compartments on the chip, allowing for a parallel and quantitative marker-less detection on a single particle level. Specific identification is possible for future devices using (integrated) molecular methods with reduced cross-contamination and without a priori virus identification.
Status
CLOSEDCall topic
ERC-2018-PoCUpdate Date
27-04-2024
Images
No images available.
Geographical location(s)