HRMEG | HRMEG: High-resolution magnetoencephalography: Towards non-invasive corticography

Summary
To date, neuroimaging has provided a wealth of information on how the human brain works in health and disease. With functional magnetic resonance imaging (fMRI), we can obtain spatially precise information about long-lasting brain activations whereas electro- and magnetoencephalography (EEG/MEG) can track transient cortical responses at millisecond resolution. However, none of these methods excel in time-resolved detection of sustained cortical activations, which are typically reflected as bursts of gamma-range (30–150 Hz) oscillations, frequently present in invasive recordings in patients. Although we have recently demonstrated that in exceptional situations MEG can detect even single gamma responses, their signal-to-noise ratio is usually prohibitively low, largely due to the substantial distance (4–5 cm) between cortex and sensors. Here, I propose to exploit recent advances in a novel magnetic sensor technology—atomic magnetometry—to construct a new kind of MEG system that allows capturing cerebral magnetic fields within millimetres from the scalp. Our simulations show that this proximity leads up to a 5-fold increase in the signal amplitude and an order-of-magnitude improvement of spatial resolution compared to conventional MEG. Therefore, a high-resolution MEG (HRMEG) system based on atomic magnetometers should enable non-invasive recordings of cortical activity at unprecedented sensitivity and detail level, which I propose to capitalize on by characterizing cortical responses, particularly gamma oscillations, during complex cognitive tasks. Additionally, since atomic magnetometers can recover within milliseconds from fields of several tesla, I also propose to combine transcranial magnetic stimulation (TMS) with MEG, leveraging the reciprocity of TMS and MEG and thus allowing better-than-ever characterization of TMS-evoked responses. This proposal comprises the research towards a HRMEG system and its application to study the working human brain in a new way.
Unfold all
/
Fold all
More information & hyperlinks
Web resources: https://cordis.europa.eu/project/id/678578
Start date: 01-09-2016
End date: 31-08-2022
Total budget - Public funding: 1 498 806,00 Euro - 1 498 806,00 Euro
Cordis data

Original description

To date, neuroimaging has provided a wealth of information on how the human brain works in health and disease. With functional magnetic resonance imaging (fMRI), we can obtain spatially precise information about long-lasting brain activations whereas electro- and magnetoencephalography (EEG/MEG) can track transient cortical responses at millisecond resolution. However, none of these methods excel in time-resolved detection of sustained cortical activations, which are typically reflected as bursts of gamma-range (30–150 Hz) oscillations, frequently present in invasive recordings in patients. Although we have recently demonstrated that in exceptional situations MEG can detect even single gamma responses, their signal-to-noise ratio is usually prohibitively low, largely due to the substantial distance (4–5 cm) between cortex and sensors. Here, I propose to exploit recent advances in a novel magnetic sensor technology—atomic magnetometry—to construct a new kind of MEG system that allows capturing cerebral magnetic fields within millimetres from the scalp. Our simulations show that this proximity leads up to a 5-fold increase in the signal amplitude and an order-of-magnitude improvement of spatial resolution compared to conventional MEG. Therefore, a high-resolution MEG (HRMEG) system based on atomic magnetometers should enable non-invasive recordings of cortical activity at unprecedented sensitivity and detail level, which I propose to capitalize on by characterizing cortical responses, particularly gamma oscillations, during complex cognitive tasks. Additionally, since atomic magnetometers can recover within milliseconds from fields of several tesla, I also propose to combine transcranial magnetic stimulation (TMS) with MEG, leveraging the reciprocity of TMS and MEG and thus allowing better-than-ever characterization of TMS-evoked responses. This proposal comprises the research towards a HRMEG system and its application to study the working human brain in a new way.

Status

CLOSED

Call topic

ERC-StG-2015

Update Date

27-04-2024
Images
No images available.
Geographical location(s)
Structured mapping
Unfold all
/
Fold all
Horizon 2020
H2020-EU.1. EXCELLENT SCIENCE
H2020-EU.1.1. EXCELLENT SCIENCE - European Research Council (ERC)
ERC-2015
ERC-2015-STG
ERC-StG-2015 ERC Starting Grant