DYMAN | DYnamically MANaged self-cooling HPC Data Centers

Summary
DYMAN targets the development of a completely new design of adsorption chillers based on the following innovations (1) New low-temperature adsorbents achieving high capacities at very low driving temperatures below 50 °C. (2) New type of adsorption heat exchangers made of 3D printed structures integrating the adsorption material into a porous structure, which reduces the internal thermal resistances and improvement of heat transfer by two-phase flow, enhancing the heat transfer rate and reducing the internal electricity consumption of the unit. Additionally the project aims to develop at second core concept to further develop an existing two-phase cooling system, for high-performance computing servers to handle thermal loads more efficiently from next-generation processors. Goals include increasing cooling capacities for processors generating high heat fluxes like the Nvidia H100 chip which produces 70 W/cm2. An additional objective is to recover 50% of waste heat from processors to generate additional cooling power through a sorption heat pump. Combining two-phase cooling directly with heat-powered cooling could significantly improve efficiency over conventional air or water-based cooling methods alone. The objective here is to 1)further develop the present two-phase cooling system to work in an efficient way in combination with the sorption heat pump (concept 1) 2) Development of new evaporator with new advanced surfaces for high heat transfer coefficients (3) Development of new condenser integrated with the heat adsorber of sorption heat pump. This is a crucial component that can improve the efficiency of the whole integrated system to recovery up to 50% of rejected heat. Furthermore, the cooling data center management is a complex engineering system with interactions with different components of the data centers. So, DYMAN proposes a new way of active management of the data center integrating the cooling system as part of the optimization of processor management
Unfold all
/
Fold all
More information & hyperlinks
Web resources: https://cordis.europa.eu/project/id/101161930
Start date: 01-07-2024
End date: 30-06-2027
Total budget - Public funding: 3 999 000,00 Euro - 3 999 000,00 Euro
Cordis data

Original description

DYMAN targets the development of a completely new design of adsorption chillers based on the following innovations (1) New low-temperature adsorbents achieving high capacities at very low driving temperatures below 50 °C. (2) New type of adsorption heat exchangers made of 3D printed structures integrating the adsorption material into a porous structure, which reduces the internal thermal resistances and improvement of heat transfer by two-phase flow, enhancing the heat transfer rate and reducing the internal electricity consumption of the unit. Additionally the project aims to develop at second core concept to further develop an existing two-phase cooling system, for high-performance computing servers to handle thermal loads more efficiently from next-generation processors. Goals include increasing cooling capacities for processors generating high heat fluxes like the Nvidia H100 chip which produces 70 W/cm2. An additional objective is to recover 50% of waste heat from processors to generate additional cooling power through a sorption heat pump. Combining two-phase cooling directly with heat-powered cooling could significantly improve efficiency over conventional air or water-based cooling methods alone. The objective here is to 1)further develop the present two-phase cooling system to work in an efficient way in combination with the sorption heat pump (concept 1) 2) Development of new evaporator with new advanced surfaces for high heat transfer coefficients (3) Development of new condenser integrated with the heat adsorber of sorption heat pump. This is a crucial component that can improve the efficiency of the whole integrated system to recovery up to 50% of rejected heat. Furthermore, the cooling data center management is a complex engineering system with interactions with different components of the data centers. So, DYMAN proposes a new way of active management of the data center integrating the cooling system as part of the optimization of processor management

Status

SIGNED

Call topic

HORIZON-EIC-2023-PATHFINDERCHALLENGES-01-01

Update Date

19-12-2024
Images
No images available.
Geographical location(s)
Structured mapping
Unfold all
/
Fold all
Horizon Europe
HORIZON.3 Innovative Europe
HORIZON.3.1 The European Innovation Council (EIC)
HORIZON.3.1.0 Cross-cutting call topics
HORIZON-EIC-2023-PATHFINDERCHALLENGES-01
HORIZON-EIC-2023-PATHFINDERCHALLENGES-01-01 EIC Pathfinder Challenge: Clean and efficient cooling