Results of continuous testing with different fuels and oxygen carriers

Summary
Results of chemical looping gasification tests a 1.5 kWth reactor at CSIC and a 10 kWth reactor at CTH with several types of fresh and pre-treated biomass operated at different temperatures and gas flows; Selection of an oxygen carrier for pilot testing